D-COAX, INC. • 8201 Jade Tree Ln.
Knoxville, TN 37938 USA
Ph: 503-550-9434 • info@d-coax.com
The OmniJet probe by D-COAX is used for highfrequency PCB impedance characterization or high-speed electrical signal analysis and is an excellent and affordable solution. It is similar to Omni probe, but it’s mounted on the compact rigid holding fixture. This compact configuration is designed for low profile PCB boards. High accuracy measurement obtained by having low contact resistance and impedance control of the probe throughout all transitions.
Tips for using OmniJet Probe:
The Omni probe uses spring pins for all contacts. The best repeatable height for probe positioning is obtained by the following method: First, over travel the probe until the probe head surface touches the DUT surface, then raise it back 0.020 inches for the best repeatable results.
The use of spring-loaded probe tips makes the probe last longer than conventional probes without losing performance or accuracy. The probe head has gold plated, rugged, crown tips that can be used for smooth or rough surfaces.
Features and Benefits
Durability - long life time, anti-crash feature, reliable contact quality
Flexibility – works on rough surface, symmetry in 4 directions
RF Performance - low insertion loss, low contact resistance, high bandwidth